Drawing № TVC-403 · Sizing

Pressure tank sizing calculator

Size a well-pump pressure tank by the drawdown method: pump flow × minimum run time, divided by the drawdown factor for your pressure switch and precharge. Every factor is computed from Boyle's law, not read from a rounded table.

Use the pump's flow at the pressure-switch range, not its open-discharge rating — the pump curve or the installer's flow test gives it. The precharge follows the switch setting (cut-in − 2 psi) until you type your own.

How the size is worked out

Required drawdown
drawdown = pump gpm × minimum run time (min)
Drawdown factor (Boyle's law)
DF = (Ppre + 14.7) ÷ (Pin + 14.7) − (Ppre + 14.7) ÷ (Pout + 14.7)
Minimum total tank volume
V = drawdown ÷ DF

With the precharge equal to cut-in, the factor simplifies to Amtrol's published form, AF = 1 − (Pin + 14.7) ÷ (Pout + 14.7). Pressures are gauge (psig); 14.7 converts them to absolute.

Pentair's worked example. An 8 gpm pump on 30/50 for 1 minute: 8 ÷ 0.30 = 26.7 gal minimum. The exact factor is 0.309, giving 25.9 gal; Pentair rounds the factor down, which errs toward the bigger tank.

Drawdown factor by pressure switch setting
SwitchPublished (precharge = cut-in)Amtrol prechargeFactor at that prechargeTank for 10 gpm × 1 min
20/40 psi0.36618 psi0.34529.0 gal
30/50 psi0.30928 psi0.29533.9 gal
40/60 psi0.26838 psi0.25838.8 gal
50/70 psi0.23648 psi0.22943.7 gal
60/80 psi0.21158 psi0.20648.7 gal
Amtrol Well-X-Trol total volume and drawdown (gal), precharge = cut-in
ModelTotal volume30/5040/6050/70
WX-1012 gal0.60.50.5
WX-1024.4 gal1.41.21.0
WX-1036.7 gal2.11.81.6
WX-10410.3 gal3.22.82.4
WX-200 / 20114 gal4.33.73.3
WX-20220 gal6.25.44.7
WX-202XL26 gal8.07.06.1
WX-20332 gal9.98.67.6
WX-20534 gal10.59.18.0
WX-25044 gal13.611.810.4
WX-25162 gal19.216.614.6
WX-25581 gal25.021.719.1
WX-30286 gal26.623.020.3
WX-350119 gal36.831.928.1

The drawdown columns reproduce Amtrol's MC7025 card to one decimal place. Pentair's composite WellMate tanks follow the same Boyle's-law factors; steel tanks with a maximum acceptance factor must also stay inside it.

FAQ

TVC-403/FAQ
What size pressure tank do I need?

Multiply the pump's flow in gallons per minute by the minimum run time (Amtrol uses 1 minute for pumps up to ¾ hp and 2 minutes above), then divide by the drawdown factor for your pressure switch. A 10 gpm pump on a 40/60 switch with a 38 psi precharge needs 10 ÷ 0.258 ≈ 39 gallons of total tank volume.

What is drawdown?

The water the tank delivers between the pump shutting off at cut-out pressure and starting again at cut-in. It is only a fraction of the tank's total volume — about a quarter on a 40/60 switch — because the air cushion has to stay compressed.

Why does the pump need a minimum run time?

Every start heats the motor and wears the pressure switch and starting components. A tank big enough for a minute or more of pumping between starts keeps the number of starts per hour down. Check your pump maker's minimum — some ask for more than Amtrol's 1 and 2 minutes.

What should the pressure tank precharge be?

Amtrol's instructions: 2 psi below the pressure-switch cut-in, with the tank empty of water — 38 psi for a 40/60 switch, 28 psi for 30/50. Pentair ships its Pro-Source steel tanks at 40 psi for 40/60 systems; follow the instructions for the tank you have.

Why is the drawdown factor slightly smaller with the 2 psi lower precharge?

A lower precharge leaves a little water in the tank when the pump cuts in, and that water is never delivered. Manufacturers' published drawdown tables assume precharge equals cut-in; the calculator works from your actual precharge, so its figure is a few percent smaller and the recommended tank a little larger.

Sources and standards

  1. Well-X-Trol Commercial Sizing (9017-102, 03/19)AMTROL Inc. (manufacturer)https://www.amtrol.com/wp-content/uploads/2019/06/9017-102-03_19-WXT-Sizing.pdfAF = 1 − (P2 + 14.7) ÷ (P3 + 14.7); TV = ESP volume ÷ AF.
  2. Well-X-Trol Sizing Card (MC7025, 03/26)AMTROL Inc. (manufacturer)https://www.amtrol.com/wp-content/uploads/2026/03/MC7025-03_26-WXT-card.pdfModel total volumes and drawdowns at 30/50, 40/60 and 50/70; 1-minute run time up to ¾ hp, 2 minutes above.
  3. Well-X-Trol Installation & Operation Manual (9015-868 / MC10185, 07/25)AMTROL Inc. (manufacturer)https://www.amtrol.com/wp-content/uploads/2025/08/9015-868-MC10185-07_25-WXT-IO-manual.pdfSet the precharge 2 psig below the pressure-switch cut-in (38 psig for a 40/60 switch).
  4. WellMate Composite Pressure Tank Catalog (WM900, 09-01-23), drawdown factor tablePentair (manufacturer)https://pentair.com/content/dam/extranet/web/nam/wellmate/catalogs/wm900-composite-pressure-tank-cat.pdfDrawdown factors based on Boyle's law (e.g. .309 at 30/50, .268 at 40/60); worked example 8 gpm × 1 min ÷ .30 = 26.7 gal.
  5. Pro-Source Steel Pressure Tanks Data Sheet (M9134WS, 09-15-2021)Pentair (manufacturer)https://flowandfiltrationsolutions.pentair.com/content/dam/extranet/web/nam/pro-source/data-sheets/m9134ws-steel-tanks-ds.pdf“Size tank for one gallon of drawdown for each gallon per minute at pump capacity.”

Every linked source above was retrieved and checked on 2026-11-01.